MP0® series

The small all-rounders for mobile coating thickness measurement.

Leading industrial instrument series for fast and easy coating thickness measurement in corrosion protection and industrial applications. 

 

Measured values shown in
two displays
Ergonomic
design
Compact:
fits in every pocket

Tactile coating thickness measurement for your pocket.

Practical to use and easy to handle, the measuring devices of the MP0® series are a compact solution for simple coating thickness measurement onsite. With two illuminated displays, a robust housing and an intuitive user interface, they are your ideal companion. Use these small handheld gauges to measure coating thicknesses (e. g. paint coating thickness or hot-dip galvanized coating thickness) on practically all metals quickly, easily and non-destructively.

Perfect fit.

The devices of the DUALSCOPE® family automatically select the right test method for your measuring task

Flexible.

Available in many different configurations depending on requirements

Compact.

Fits in any pocket

Up to all challenges.

Precise measurement on many surfaces in a wide range of coating thicknesses

Built to last.

Suitable for thousands of measurements thanks to low wear probe pole

Ideal for onsite use.

Compact design and 2-display solution

  • Features

      Measuring method: Magnetic induction and amplitude-sensitive eddy current

      Measuring range: DUALSCOPE®: 0 - 2,000 µm / ISOSCOPE®: 0 - 1,200 µm / PERMASCOPE®: 0 - 2,500 µm

      High-precision conductivity compensation

      Measured value memory: 10,000 or 1,000 in one application, depending on the device

      Probe integrated in the device, FP(W) models with connected probe for a wide range of applications

      Pre-installed measurement modes for thickness measurement according to IMO PSPC or SSPC-PA2 (MP0®R)

      Limit value monitoring via light

Overview of the MP0® series and application examples

DUALSCOPE® MP0®
ISOSCOPE® MP0®
PERMASCOPE® MP0®

Measuring method:

Amplitude-sensitive eddy current method and magnetic induction measuring method

Applications:

Measurement of non-magnetic or electrically non-conductive layers on magnetic or non-magnetic, electrically conductive base materials

Application examples:

  • Coating thickness measurements on steel and non-ferrous metals
  • Zinc, chrome, copper, paint, varnish or plastic coatings on steel, iron or cast iron
  • Paint, lacquer or plastic coatings on aluminum, copper or brass
  • Anodized coatings on aluminium
  • Suitable for smooth and rough surfaces

Do you have other applications? Then contact us!

 

DUALSCOPE® MP0® coating system

Measuring method:

Amplitude-sensitive eddy current method

Applications:

Measuring electrically insulating layers on non-magnetic, electrically conductive metals

Application examples:

  • Precise coating thickness measurements on practically all non-ferrous metals
  • Paint, lacquer or plastic coatings on aluminum, copper or brass
  • Anodized coatings on aluminium

Do you have other applications? Then contact us!

 

ISOSCOPE® MP0® coating system

Measuring method:

Magnetic induction measuring method

Applications:

Measurement of non-magnetic layers on magnetic base materials

Application examples:

  • Precise coating thickness measurements of thin layers on steel and iron
  • Zinc, chrome, copper, paint, varnish or plastic coatings on steel, iron or cast iron
  • Coating thickness measurements on smooth and rough surfaces

Do you have other applications? Then contact us!

 

PERMASCOPE® MP0® coating system
  • DUALSCOPE® MP0®

      Measuring method:

      Amplitude-sensitive eddy current method and magnetic induction measuring method

      Applications:

      Measurement of non-magnetic or electrically non-conductive layers on magnetic or non-magnetic, electrically conductive base materials

      Application examples:

      • Coating thickness measurements on steel and non-ferrous metals
      • Zinc, chrome, copper, paint, varnish or plastic coatings on steel, iron or cast iron
      • Paint, lacquer or plastic coatings on aluminum, copper or brass
      • Anodized coatings on aluminium
      • Suitable for smooth and rough surfaces

      Do you have other applications? Then contact us!

       

      DUALSCOPE® MP0® coating system
  • ISOSCOPE® MP0®

      Measuring method:

      Amplitude-sensitive eddy current method

      Applications:

      Measuring electrically insulating layers on non-magnetic, electrically conductive metals

      Application examples:

      • Precise coating thickness measurements on practically all non-ferrous metals
      • Paint, lacquer or plastic coatings on aluminum, copper or brass
      • Anodized coatings on aluminium

      Do you have other applications? Then contact us!

       

      ISOSCOPE® MP0® coating system
  • PERMASCOPE® MP0®

      Measuring method:

      Magnetic induction measuring method

      Applications:

      Measurement of non-magnetic layers on magnetic base materials

      Application examples:

      • Precise coating thickness measurements of thin layers on steel and iron
      • Zinc, chrome, copper, paint, varnish or plastic coatings on steel, iron or cast iron
      • Coating thickness measurements on smooth and rough surfaces

      Do you have other applications? Then contact us!

       

      PERMASCOPE® MP0® coating system
  • Model differences in detail

      MP0® MP0®R
      Model
      MP0®
      "Basic model"
      MP0®-FP
      "Basic model"
      MP0®R
      "Comfort model"
      MP0®R-FP
      "Comfort model"
      MP0®R-FPW
      "Comfort model"
      Probe
      Integrated in the devicePermanently connected cable probe for hard-to-reach places
      Integrated in the devicePermanently connected cable probe for hard-to-reach areasPermanently connected angled cable probe for challenging geometries
      Available devices
      DUALSCOPE®, PERMASCOPE®
      DUALSCOPE®, ISOSCOPE®,
      PERMASCOPE®
      DUALSCOPE®, PERMASCOPE®DUALSCOPE®, PERMASCOPE®
      Usage and application
      Find out more about the applications here.
      Find out more about the applications here.
      Measuring method

      Amplitude-sensitive eddy current method AND magnetic induction measuring method (DUALSCOPE®)

      Magnetic induction measuring method (PERMASCOPE®)

      Amplitude-sensitive eddy current method AND magnetic induction measuring method (DUALSCOPE®)

      Amplitude-sensitive eddy current method (ISOSCOPE®)

      Magnetic induction measuring method (PERMASCOPE®)

      Amplitude-sensitive eddy current method AND magnetic induction measuring method (DUALSCOPE®)

      Magnetic induction measuring method (PERMASCOPE®)

      Measured value memory
      1,000
      10,000
      Number of measuring tasks
      1
      1
      Data transfer
      -
      Via USB
      Measurement modes
      -
      Pre-installed according to IMO PSPC or SSPC-PA2
      Rotatable display
      -
      Automatically rotating display
      MP0®
      Model
      MP0®
      "Basic model"
      MP0®-FP
      "Basic model"
      Probe
      Integrated in the devicePermanently connected cable probe for hard-to-reach places
      Available devices
      DUALSCOPE®, PERMASCOPE®
      Usage and application
      Find out more about the applications here.
      Measuring method

      Amplitude-sensitive eddy current method AND magnetic induction measuring method (DUALSCOPE®)

      Magnetic induction measuring method (PERMASCOPE®)

      Measured value memory
      1,000
      Number of measuring tasks
      1
      Data transfer
      -
      Measurement modes
      -
      Rotatable display
      -
      MP0®R
      Model
      MP0®R
      "Comfort model"
      MP0®R-FP
      "Comfort model"
      MP0®R-FPW
      "Comfort model"
      Probe
      Integrated in the devicePermanently connected cable probe for hard-to-reach areasPermanently connected angled cable probe for challenging geometries
      Available devices
      DUALSCOPE®, ISOSCOPE®,
      PERMASCOPE®
      DUALSCOPE®, PERMASCOPE®DUALSCOPE®, PERMASCOPE®
      Usage and application
      Find out more about the applications here.
      Measuring method

      Amplitude-sensitive eddy current method AND magnetic induction measuring method (DUALSCOPE®)

      Amplitude-sensitive eddy current method (ISOSCOPE®)

      Magnetic induction measuring method (PERMASCOPE®)

      Amplitude-sensitive eddy current method AND magnetic induction measuring method (DUALSCOPE®)

      Magnetic induction measuring method (PERMASCOPE®)

      Measured value memory
      10,000
      Number of measuring tasks
      1
      Data transfer
      Via USB
      Measurement modes
      Pre-installed according to IMO PSPC or SSPC-PA2
      Rotatable display
      Automatically rotating display

Fischer Insights.

Measuring method.

Find out here what we can measure for you.

Learn more
Services.

We offer you everything you need for reliable measurement results.

Learn more
Why Fischer.

Experience many good reasons that speak for us as a company.

Learn more

Discover more products.