Check out our new FISCHERSCOPE® XDAL® and XDV®, together with the cutting-edge FISIQ® X software. Learn more!

DMP®10-40 series

Product may vary based on model or features

The multi-talented series for coating thickness measurement.

Thanks to its enormously wide probe portfolio, the DMP®10-40 series is our universal device series for tactile coating thickness and dry film thickness measurement.

Robust and durable thanks to
all-aluminum housing and IP64
Limit monitoring via
light, sound and vibration ¹
Unique data handling
functions
¹ Show more
Show less

¹ Vibrating alarm available for DUALSCOPE® DMP®40, DELTASCOPE® DMP®30 and ISOSCOPE® DMP®30.

The next level of tactile coating thickness measurement.

The robust handheld devices of our DMP® family are versatile and suitable for a wide range of applications, particularly in quality assurance. With extensive functionality, a broad selection of probes, and unique data handling functions, these devices are the perfect solution for your non-destructive coating thickness measurement on ferrous and non-ferrous base materials.

Built to last.

Next level quality and durability thanks to all-aluminum housing

Full measuring control.

Feedback via light, sound and vibration whether measured values are within tolerance

Perfect fit.

Measure 24/7 due to quick and easy battery change

Digital probes.

Fully digitized probes for the most demanding measurement tasks

Powerful FISIQ® T software.

Automatic device recognition, easy data export, and comprehensive reporting
Discover more

Unique data handling functions.

Via REST API, simulated keyboard entry, Excel export, or freely programmable Bluetooth communication with the customer‘s software
Discover more

  • Features

      Measuring method: Magnetic induction and amplitude-sensitive eddy current method

      Digital probes available for a wide range of applications, analog probes backwards compatible thanks to F-adapter

      Measuring range: Depending on the combination of coating and base material and the used probe

      Automatic device detection and easy data transfer via USB-C and Bluetooth, depending on the device

      Measured value memory: 10,000 in one batch or 250,000 in 2,500 batches, depending on the device

      Robust aluminum housing with protection class IP64

      Most powerful software in tactile coating thickness measurement: FISIQ® T

      Replaceable Li-Ion battery for > 24 h operating time

      Limit monitoring via light, sound and vibration, depending on the device

Overview of the DMP® series and application examples

DUALSCOPE® DMP®
ISOSCOPE® DMP®
DELTASCOPE® DMP®

Measuring method:

Amplitude-sensitive eddy current method and magnetic inductive measuring method

Applications:

Measurement of non-magnetic or electrically non-conductive coatings on magnetic or non-magnetic, electrically conductive base materials

Application examples:

  • ISO on NF: Paint, lacquer or plastic coatings on Al, Cu, CuZn
  • ISO on NF: Anodized layers on Al
  • ISO on FE: Paint, lacquer, plastic coatings on Fe, steel
  • NFE on FE: Zn, Cr, Cu on Fe, steel

Do you have other applications? Then contact us!

 

DUALSCOPE® DMP® shift system

Measuring method:

Amplitude-sensitive eddy current method

Applications:

Measurement of electrically insulating coatings on non-magnetic, electrically conductive metals

Application examples:

  • ISO on NF: Paint, lacquer or plastic coatings on Al, Cu, CuZn
  • ISO on NF: Anodized layers on Al

Do you have other applications? Then contact us!

ISOSCOPE® DMP® coating system

Measuring method:

Magnetic inductive measuring method

Applications:

Measurement of non-magnetic coatings on magnetic base materials

Application examples:

  • ISO on FE: Paint, lacquer, plastic coatings on Fe, steel
  • NF on FE: Zn, Cr, Cu on Fe, steel

Do you have other applications? Then contact us!

 

DELTASCOPE® DMP® coating system
  • DUALSCOPE® DMP®

      Measuring method:

      Amplitude-sensitive eddy current method and magnetic inductive measuring method

      Applications:

      Measurement of non-magnetic or electrically non-conductive coatings on magnetic or non-magnetic, electrically conductive base materials

      Application examples:

      • ISO on NF: Paint, lacquer or plastic coatings on Al, Cu, CuZn
      • ISO on NF: Anodized layers on Al
      • ISO on FE: Paint, lacquer, plastic coatings on Fe, steel
      • NFE on FE: Zn, Cr, Cu on Fe, steel

      Do you have other applications? Then contact us!

       

      DUALSCOPE® DMP® shift system
  • ISOSCOPE® DMP®

      Measuring method:

      Amplitude-sensitive eddy current method

      Applications:

      Measurement of electrically insulating coatings on non-magnetic, electrically conductive metals

      Application examples:

      • ISO on NF: Paint, lacquer or plastic coatings on Al, Cu, CuZn
      • ISO on NF: Anodized layers on Al

      Do you have other applications? Then contact us!

      ISOSCOPE® DMP® coating system
  • DELTASCOPE® DMP®

      Measuring method:

      Magnetic inductive measuring method

      Applications:

      Measurement of non-magnetic coatings on magnetic base materials

      Application examples:

      • ISO on FE: Paint, lacquer, plastic coatings on Fe, steel
      • NF on FE: Zn, Cr, Cu on Fe, steel

      Do you have other applications? Then contact us!

       

      DELTASCOPE® DMP® coating system
  • Model differences in detail

      DUALSCOPE® DELTASCOPE® ISOSCOPE®
      Model
      DUALSCOPE®
      DMP®20
      "Entry-level model"
      DUALSCOPE®
      DMP®40
      "Comfort model"
      DELTASCOPE®
      DMP®10
      "Entry-level model"
      DELTASCOPE®
      DMP®30
      "Comfort model"
      ISOSCOPE®
      DMP®10
      "Entry-level model"
      ISOSCOPE®
      DMP®30
      "Comfort model"
      Application
      Measurement of non-magnetic or electrically non-conductive coatings on magnetic or non-magnetic, electrically conductive base materials
      Measurement of non-magnetic coatings on magnetic base materials
      Measurement of electrically insulating coatings on non-magnetic, electrically conductive metals
      Base material
      Non-ferrous metal (NF) and steel or iron (FE)
      Steel or iron (FE)
      Non-ferrous metal (NF)
      Application examples
      • Paint, lacquer or plastic coatings on aluminum, copper or brass (ISO/NF)
      • Anodized coatings on aluminium (ISO/NF)
      • Zinc, chrome, copper coatings on steel or iron (NF/FE)
      • Paint, lacquer, plastic coatings on steel or iron (ISO/FE)
      • Zinc, chrome, copper coatings on steel or iron (NF/FE)
      • Paint, lacquer, plastic coatings on steel or iron (ISO/FE)
      • Paint, lacquer or plastic coatings on aluminum, copper or brass (ISO/NF)
      • Anodized coatings on aluminium (ISO/NF)
      Measuring method
      Amplitude-sensitive eddy current method AND Magnetic inductive measuring method
      Magnetic inductive measuring method
      Amplitude-sensitive eddy current method
      Measured value memory
      ≤ 10,000≤ 250,000
      ≤ 10,000≤ 250,000
      ≤ 10,000≤ 250,000
      Number of measuring tasks
      1≤ 2,500
      1≤ 2,500
      1≤ 2,500
      Communication
      USB-CUSB-C and Bluetooth
      USB-CUSB-C and Bluetooth
      USB-CUSB-C and Bluetooth
      Limit value monitoring
      Light and soundLight, sound and vibration
      Light and soundLight, sound and vibration
      Light and soundLight, sound and vibration
      Standards
      DIN EN ISO 2178, DIN EN ISO 2360, ASTM D7091, ASTM 4471
      DIN EN ISO 2178, ASTM D7091, ASTM 4471
      DIN EN ISO 2360, ASTM D7091, ASTM 4471
      DUALSCOPE®
      Model
      DUALSCOPE®
      DMP®20
      "Entry-level model"
      DUALSCOPE®
      DMP®40
      "Comfort model"
      Application
      Measurement of non-magnetic or electrically non-conductive coatings on magnetic or non-magnetic, electrically conductive base materials
      Base material
      Non-ferrous metal (NF) and steel or iron (FE)
      Application examples
      • Paint, lacquer or plastic coatings on aluminum, copper or brass (ISO/NF)
      • Anodized coatings on aluminium (ISO/NF)
      • Zinc, chrome, copper coatings on steel or iron (NF/FE)
      • Paint, lacquer, plastic coatings on steel or iron (ISO/FE)
      Measuring method
      Amplitude-sensitive eddy current method AND Magnetic inductive measuring method
      Measured value memory
      ≤ 10,000≤ 250,000
      Number of measuring tasks
      1≤ 2,500
      Communication
      USB-CUSB-C and Bluetooth
      Limit value monitoring
      Light and soundLight, sound and vibration
      Standards
      DIN EN ISO 2178, DIN EN ISO 2360, ASTM D7091, ASTM 4471
      DELTASCOPE®
      Model
      DELTASCOPE®
      DMP®10
      "Entry-level model"
      DELTASCOPE®
      DMP®30
      "Comfort model"
      Application
      Measurement of non-magnetic coatings on magnetic base materials
      Base material
      Steel or iron (FE)
      Application examples
      • Zinc, chrome, copper coatings on steel or iron (NF/FE)
      • Paint, lacquer, plastic coatings on steel or iron (ISO/FE)
      Measuring method
      Magnetic inductive measuring method
      Measured value memory
      ≤ 10,000≤ 250,000
      Number of measuring tasks
      1≤ 2,500
      Communication
      USB-CUSB-C and Bluetooth
      Limit value monitoring
      Light and soundLight, sound and vibration
      Standards
      DIN EN ISO 2178, ASTM D7091, ASTM 4471
      ISOSCOPE®
      Model
      ISOSCOPE®
      DMP®10
      "Entry-level model"
      ISOSCOPE®
      DMP®30
      "Comfort model"
      Application
      Measurement of electrically insulating coatings on non-magnetic, electrically conductive metals
      Base material
      Non-ferrous metal (NF)
      Application examples
      • Paint, lacquer or plastic coatings on aluminum, copper or brass (ISO/NF)
      • Anodized coatings on aluminium (ISO/NF)
      Measuring method
      Amplitude-sensitive eddy current method
      Measured value memory
      ≤ 10,000≤ 250,000
      Number of measuring tasks
      1≤ 2,500
      Communication
      USB-CUSB-C and Bluetooth
      Limit value monitoring
      Light and soundLight, sound and vibration
      Standards
      DIN EN ISO 2360, ASTM D7091, ASTM 4471

Unique data handling functions

    • Schematic drawing

      Our DMP® devices provide you with maximum flexibility for your data handling. Transfer your measurement data quickly and reliably with USB-C or Bluetooth via REST API, simulated keyboard entry, direct Excel export, or freely programmable Bluetooth communication with your own software – ensuring your data reaches exactly where you need it!

Application Notes
Product videos
Tutorials
Webinars
Brochures
DMP® series: Discover the new DMP® series
DMP®10-40 series: Introduction
DMP®10-40 series: Unboxing
Influence of curved surfaces on the measurement results and its compensation

Fischer Insights.

Measuring method.

Find out here what we can measure for you.

Learn more
Services.

We offer you everything you need for reliable measurement results.

Learn more
Why Fischer.

Experience many good reasons that speak for us as a company.

Learn more

Discover more products.